ESD
Last Updated: Feb 1st, 2008 - 10:12:17
|
See this
article in our Digital Edition Download a
pdf of this article (right click to save the
pdf)
From the late 1980s through the 1990s, damage to
electronic devices from electrostatic discharge (ESD) declined
steadily. Many companies had invested heavily in ESD programs with
handling precautions and process monitoring, and their investments paid
dividends. Additionally, design changes—the inclusion of protective
structures on the circuits themselves—created more robust circuitry
that was less vulnerable to ESD.
The early design changes, however, diminished the performance of the
electronic circuitry. To meet the demand for small, faster components,
manufacturers eliminated those circuit-protection schemes, reversing
the trend of declining ESD sensitivity. Older model electronic
components were vulnerable to human body model (HBM) discharges of 100
V or greater; today’s ultra-sensitive devices are vulnerable to charges
as low as 20 V. According to the Electrostatic Discharge Association’s
Technology Roadmap, ESD sensitivity will continue increasing, by some
estimates at least through 2010.
Ted Dangelmayer, an ESD consultant and president of Dangelmayer
Associates, describes this new class of vulnerable electronic parts as
“class 0 ESDS devices.” The emergence of these class 0 devices has
exposed the loopholes in many ESD prevention programs and created
challenges for all users of state-of-the-art electronics—from chip
manufacturers through server room and data center managers.
According to Dangelmayer, class 0 components require much more
stringent ESD controls and procedures, beginning with a complete
reassessment of root causes of ESD failures. As Dangelmayer and other
industry experts are quick to point out, most ESD programs are
predicated on protecting electronics from human body model failures at
or above 100 volts. This tactic does not protect class 0 devices from
exposure to < 100 volt HBM discharges, nor does it even come close
to addressing the far more deleterious effects of other ESD failure
models.
Class 0 Handling Is Inevitable
By 2010, virtually all factories will be handling some number of class
0 devices. It has taken those companies that have already made the
transition two years to bring their facilities up to the standards
necessary to protect their class 0 devices from ESD failure. The
decline in ESD failures during the late 1990s had lulled many companies
into an attitude of false security. As they made the transition to
class 0 handling, many companies, even those that had long-standing ESD
programs in place, were faced with a lack of ESD expertise. Naturally,
program managers, who themselves were often unsure about how or even
why to upgrade their ESD protection program, had difficulty getting
buy-in from management.
Figure 1: Class 0 devices per factory. (Copyright 2007, Dangelmayer Associates)
Proactive response to the arrival of class 0 devices is an absolute
must. The companies that will fare the best will be the ones that make
the transition before they actually begin working with ultra-sensitive
components. And that can only happen if they begin re-educating
themselves immediately.
Fortunately, interest in ESD has been increasing over the past couple
years. Internet searches on engines like www.google.com indicate a
significant rise in ESD-related searches. Attendance at ESD-related
events and conferences is up. Both indicate a growing need for
technical information and advice. The following seven issues are only
the tip of the iceberg. They are however the place to begin.
1st Consideration: Understand the Limitations of ANSI/ESD S20.20-2007
Today, technological advances are outpacing the human ability to
respond. It could take years for standards to be modified and new
standards to be generated by volunteer-led organizations. It is
imprudent to rely solely on industry standards and benchmark
recommendations that neither fully anticipate nor adequately prescribe
solutions to problems specific to state-of-the-art technology. The
responsibility to do things right— which may mean exceeding the
recommendations of generally accepted methods—always falls on the
implementer. In the case of ANSI/ESD S20.20-2007, two limitations are
clearly identified by the document’s authors.
First, as stated in the forward to ANSI//ESD S20.20-2007, “This
standard covers the requirements necessary to design, establish,
implement and maintain an Electrostatic Discharge (ESD) Control Program
for activities that manufacture, process, assemble, install, package,
label, service, test, inspect or otherwise handle electrical or
electronic parts, assemblies and equipment susceptible to damage by
electrostatic discharges greater than or equal to 100 volts Human Body
Model (HBM).”
By design, the standard does not offer a prescription for handling
sensitive components with HBM thresholds below 100 volts. S20.20 also
fails to address applications where the use of ESD controlled footwear
is impractical—such as in server rooms, data centers or call centers.
In applications where static protective footwear will not be used,
buyers should consider the recommended specifications in S20.20, and
also analyze any unusual performance parameters that apply to their
specific application. In the case of flooring, a buyer should look at
the antistatic properties of the floor not only when it’s used in
conjunction with conductive footwear, but also when it’s used with
conventional nonconductive footwear.
Second, this standard does not cover the handling of electrically
initiated explosive devices. The handling of explosives is obviously of
greater concern than the handling of ESDS components, since there is
little margin for error where safety is concerned. The fact that S20.20
does not address these concerns does not diminish its applicability to
the industry it was written to serve. It merely points out that there
are situations and applications where static must be controlled at
different levels and possibly in a more rigorous manner. As with
explosives, the handling of class 0 devices requires redundant process
controls and the use of better performing static preventive materials.
Readers can download a free copy of ANSI/ESD S20.20-2007 at http://esda.org/documents/S20.20-2007FINAL_000.pdf.
2nd Consideration: Understand the Charge Device Model
Most ESD program managers understand the human body discharge model. We
encounter this model everyday, whether we realize it or not. When
humans move, slide in chairs, remove or put on items of clothing, they
generate some amount of static electricity. When they touch another
object, that static electricity discharges; this is called the human
body model discharge. While discharges below 3500 volts are dangerous
to components, they cannot be felt by humans.
HBM threats can usually be addressed by implementing a continuous
system of grounding and electrical bonding. The three most common
examples of HBM precautions are wrist straps, conductive footwear and
ESD flooring. Properly selected and monitored, these three precautions
will eliminate almost all HBM threats. (This may require educating
skeptical personnel who, because they cannot see or feel static
electricity, question its existence.)
A less understood but potentially more destructive threat to components
is a failure model called the Charged Device Model (CDM). Assembly
Magazine, an industry journal covering manufacturing and assembly,
defines CDM as follows: “a failure model where the part in question
holds an electrostatic charge and rapidly discharges to another object
when they are brought into contact. The discharge could cause a device
failure.” An expanded technical explanation of CDM can be found at this
ESD Association link: www.esda.org/esdbasics5.htm
The CDM model is not a newly recognized failure model. B. Unger et. al.
from Bell Labs identified CDM problems in the early 1980s. In an ESD
Symposium paper, they identified at least two scenarios where a CDM
event could occur: 1) when a charged device is placed on a work surface
that is too conductive; and 2) when a charged device is placed in
highly conductive packaging. This early work is the reason companies
today use static dissipative and not conductive table covering.
One of the best examples of the CDM threat is on automated placement
equipment. If a circuit board or individual device is picked up and
placed down by a nonconductive fixture, a static charge and discharge
may occur. This is a particularly risky problem in a high volume
factory, as every part is subjected to the same threat, and the extent
of the damage cannot be determined until final test. If the electronic
parts have low CDM thresholds, the fallout could be catastrophic to a
company’s bottom line or reputation.
ANSI/ESD S.20.20 does not mention CDM failures or offer prescriptions
for reducing them. CDM failures are discussed, however, in the
Association’s ESD Technology Roadmap (available at www.esda.org). In
2005, as shown on their graph (Figure 2), minimum device sensitivity
was just below 500 volts; by 2010 the value is expected to drop to just
above zero. This increased sensitivity to CDM failure presents a major
problem for any program manager dealing with new technology in an
electronics manufacturing, test, or repair application that is not
equipped to handle an HBM threshold below 100 volts.
Figure 2: CDB and HBM thresholds will decrease to Class 0 levels by 2010. (Copyright 2007, Danglemayer Associates)
(Note that a common misunderstanding of the Bell Labs study led to the
false belief that dissipative flooring is better than conductive
flooring. In fact, flooring should not be evaluated in the same manner
as table covering. The recognized standard for ESD flooring is a
flooring-footwear system that will not exceed 35 megohms.)
3rd Consideration: Understand Induction and Voltage Suppression
While electrostatic physics can become quite complicated when the
problems involve electrets, the effects of corona treating or the
theory behind why certain materials become charged in the first place,
there are two basic principles that every ESD program manager should
understand. They are electrostatic induction and voltage suppression.
Electrostatic Induction
Electrostatic induction occurs when one object picks up a charge from
the electrostatic field of a second object. When a grounded conductor
is placed in the vicinity of an electrostatic field, because the
conductor is grounded, its voltage is zero. When it breaks from ground
while still in the presence of the electrostatic field, induction
occurs—i.e., a charge opposite that of the electrostatic field is
trapped on the conductive object.
Induction occurs when an aircraft is parked directly below a thunder
cloud and its ground connection is removed. If the aircraft fuel intake
were to reunite with ground while still charged, a CDM event would
occur, potentially causing an explosion. In a factory, an ESDS device
touches a grounded table mat; lying on or near the mat is a charged
insulative object such as plastic bag or roll of tape. When the ESDS
device is lifted from the mat, it picks up or loses electrons from the
electrostatic field around the bag or tape. If the charged device now
touches a grounded person’s finger, a circuit board or any other
conductor, the ensuing discharge could destroy the device.
It is a common misconception that the electrostatic field around a
charged insulator will cause the failure of static-sensitive devices.
Although this is possible if the device is one of the rare
field-sensitive ones, it is more likely that a problem will result from
a CDM model. Like the cloud in the aircraft example, the fields on
charged insulators can and will charge electronic devices. If the
devices are discharged to the wrong surface, the results could be
catastrophic ESD damage.
Voltage Suppression
Voltage suppression is the product of the equation relating charge,
capacitance and voltage or Q = C X V; Q is charge, V is voltage and C
is capacitance. When the capacitance of a charged object is raised, its
voltage decreases. The easiest way to understand voltage suppression is
by performing a simple experiment. This requires two items: a static
field meter and a small sheet of clear plastic like the ones used to
hold paper in a 3-ring binder.
Directions:
- Place
the plastic flat against a wall while rubbing it vigorously with the
back of your hand. Static electricity will cause the plastic to stick
to the wall.
- While
the plastic is stuck to the wall, measure it with the static meter.
Unless the wall is plastic, the static meter will read at or close to
zero.
- Maintaining
a constant distance between plastic and meter, slowly pull the plastic
off the wall. The meter will suddenly register thousands of volts.
- Gently
allow the plastic sheet to reattach to the wall. The plastic will once
again measure at or near zero. Where did the charge go?
Although this may seem like an aberrant situation, it is not, since
static meters do not actually measure charge. Instead, static meters
measure voltage. When the plastic is stuck to the wall, the
capacitance—ratio of charge to potential on an electrically charged,
isolated conductor—is high, so the voltage is low. When the plastic is
in free space, because it is no longer sharing space with the wall, the
capacitance is low, so the voltage is high. In both cases, the charge
was and is the same. It did not appear that way because of what we call
voltage suppression.
Voltage suppression can cause serious problems for ESD program
managers. For example, troublesome insulators like sheet protectors
could be highly charged; but, if they are resting on a flat surface,
even if the static meter is placed directly over them, their charge
cannot be detected. To ensure a correct reading with a static meter,
suspicious objects should be lifted, frictioned and measured in free
space to determine if they are potential problems.
When evaluating ESD work and flooring surfaces, particularly those with
a buried conductive layer, it is important to determine whether the
material pulls static away from charged objects or merely suppresses
their electrostatic field. ESD table laminates, for instance, suppress
but do not actually discharge items that are placed on them. Because of
design flaws and contact resistance issues, it is very difficult for
any hard surface table covering to bleed off voltages below 50 volts.
Resilient, lower durometer work surfaces should be installed in lieu of
or on top of ESD laminates.
ESD floors are routinely tested for HBM discharge by attaching a person
to a charge plate monitor with a wire or a wrist strap. To test the
floor properly, the person standing on the flooring material should
move his or her feet, periodically breaking ground. If the subject
retains a static charge when the feet are lifted, the ESD control
material is merely suppressing the charge. A properly functioning ESD
floor should bleed accumulated charges away from the person; when his
or her feet are lifted, the voltage should remain at or close to zero.
The full method for performing body voltage measurements is described
in ANSI/ESD STM97.2.
4th Consideration: Prevention Usually Trumps the Cure
Many ESD program managers implement safety nets and redundant
precautions such as ionizers, expensive ground monitors and cumbersome
packaging techniques. These precautions are often unnecessary and could
actually threaten rather than protect class 0 sensitive devices.
One good example of an over-prescribed cure is the use of bench-top air
ionizers. Air ionizers produce positive and negative ions that
neutralize charged objects if the charged object has an electrostatic
field. Air ionizers effectively eliminate static only on stationary or
slow-moving, low-capacitance, charged objects at close range. Air
ionizers will not reduce static on fast-moving pick and place equipment
if the air curtain is obstructed or if the ions must travel into a
small space surrounded by grounded metal. Air ionizers also do not
reduce static on human beings or on charged objects such as sheet
protectors that are resting on a flat surface (capacitance is too high;
there is no field to neutralize).
Worse, when they malfunction, air ionizers can pose unanticipated
threats to class 0 devices. Contamination or mechanical problems can
cause air ionizers to become unbalanced. An unbalanced air ionizer can
deposit a charge equal to the amount of the imbalance, causing a CDM
failure. A 20 volt imbalance that had no impact on older ESD-hardened
components would be unacceptable in a class 0 ESD environment.
Ninety percent of all ionizers are installed to neutralize charged
objects that find their way into the workplace. A solution that’s
better than neutralizing charged insulators is not to use them. Before
buying ionizers, ESD program managers should consider eliminating
specific static generators, such as plastic tweezers, masking tapes and
the interfaces on certain placement equipment. Most insulative
production aids are available in antistatic or dissipative form.
Plastics and other non-essential insulative items should be removed or
banned from places where ESD-sensitive devices are being handled, used
or repaired. Ionizers should be purchased only after all other
preventive alternatives have been exhausted.
5th Consideration: When Buying, Look Beyond Spec Sheets
Often, specifications are derived from test methods that do not predict
performance for a particular application. Reliance on inappropriate
test methods can lead buyers in the wrong direction. For example,
carpet manufactures use the AATCC134 test method to specify the
antistatic properties of their product. This standard textile industry
test method, designed for conventional carpet, is irrelevant for
applications involving electronic components. The test evaluates newly
manufactured carpet (one time) for walking body voltage, and tests
voltage generation only on a person wearing leather or neolite shoes.
This test does not measure conductivity, evaluate the longevity of a
carpet’s antistatic properties, or test the static generated by the
soles of more popular footwear, such as athletic shoes, hiking boots or
flip-flops.
Most standard ESD testing is done with static control footwear. These
tests, conducted under perfect conditions, do not predict what will
happen if a visitor or an employee wanders into an area with standard
footwear, or if heel or sole straps are worn improperly. In a class 0
application, people should always wear ESD protective footwear, and the
only ESD flooring materials that should be used are those that, with
ESD footwear, keep charges below 20 volts.
Obviously, it is not always possible to monitor or control the use of
static control footwear. For this reason, ESD program managers should
also evaluate the static generating potential of the floor under
various real-world conditions—e.g., with conventional footwear, by
asking the subject to lift his or her feet or to wear one heel strap
instead of two, etc. Having a full picture may enable a buyer to
justify investing in an ultra low-voltage generating conductive rubber
floor instead of a less-effective epoxy or urethane floor.
This same scrutiny should be used when purchasing air ionizers. Most
ionizer manufacturers use ANSI/ESD STM 3.1-2006 to provide data on
charge decay based on discharge times of a stationary charged plate of
a known low capacitance. If the ionizer will be used to neutralize
charges on moving placement heads on automated equipment, exposure time
should also be considered. The ionizer may be “best of class,” but that
does not mean it can neutralize a small object moving at high speeds.
6th Consideration: Buy the Right Instruments to Evaluate New Purchases and to Audit the Program
Most ESD program managers use test equipment to audit the performance
of ESD controls. Because there are numerous instruments on the market,
these purchases are almost always cost-driven. This low-cost equipment
is described as portable or easy-to-use. Portable, easy-to-use
instruments frequently do not store data and are often inadequate for
testing and evaluating materials in a class 0 environment.
The single most important use of test data is in tracking trends and
making corrections before problems arise. For example, ESD wax is a
temporary static control flooring solution, and traffic and washing
eventually diminish its electrical performance. If ESD wax is used as
the primary floor ground plane, it should be tested in multiple areas
on a constant basis. Does it really make sense to measure something as
important as the facility’s primary ground plane without collecting,
storing and evaluating multiple data points over time?
Because there is a direct correlation between body voltages (measured
per ANSI/ESD 97.2-1999) over 40 volts and flooring/footwear system
resistances (measured per ANSI/ESD STM97.1-2006) above 10 megohms,
tracking performance trends of flooring as well as other key components
is mandatory in order to safely handle class 0 components. Class 0 is
not the same as “class 100,” and materials that were good enough to
meet ANSI/ESD S20.20 could put class 0 components in jeopardy.
For class 0 applications, it makes sense to invest in quality
instruments. After all, data is only as reliable as the instrument used
to do the testing. The pricier instruments accurately measure, store
and download data. Used correctly, this longitudinal information can
prevent a critical breach in the ESD prevention program. The collection
and use of quality data could help justify investment in long-term
solutions instead of band-aids like ESD waxes, floor mats and paints.
Figure 3: Ideal resistance to ground
of person wearing static control footwear in combination with ESD
flooring, per ANSI/ESD STM97.1-2006 (Copyright 2007, Staticworx)
7th Consideration: Involve an Expert
In the 1980s many electronics companies employed in-house ESD experts.
These individuals were usually members of the quality department and
theirs was the final word on whether or not ESD controls were
implemented, modified or eliminated. Outsourcing in combination with
the high tech slowdown of the 1990s eliminated this position in many
companies. Because management believed their ESD programs to be
self-maintaining, ESD coordinators were looked upon as unnecessary
overhead. This line of thinking was reinforced by the success of
on-chip ESD protection and declining ESD sensitivity.
One of the fallouts from this trend is a general lack of knowledge
about static at even the most prestigious electronics corporations. One
particular large telecom manufacturer had been using static dissipative
flooring for an application that would have been far better served by a
conductive material. When their supplier installed a more conductive
version of their flooring in a new area, an auditor noticed that the
new floor’s resistance to ground was now reading in the red zone on her
analog resistance meter. Her concerns prompted an investigation, the
auditor insisting that their new floor was “no good.” The issue was
settled only after an independent consultant was brought in to help the
client understand why conductive flooring was actually better for their
application.
The vast amount of competing information on the web has further
confused buyers about which ESD protective materials to buy and what
criteria to use when selecting them. Before the Internet, very little
information was published without first being vetted by an editorial
board. Today, anyone can become his or her own publisher—with or
without technical qualifications. ESD program managers should consider
only information gleaned from reliable sources such as industry
associations, technical publications and independent consultants.
Summary
If all the ESD specialists, physicists and device manufacturers are
correct, class 0 environments will soon be commonplace in
high-technology environments. In a class 0 environment, marginally
performing ESD solutions—a dysfunctional ionizer or static dissipative
floor—cannot be trusted to eliminate the ESD threat and may even
contribute to the problem they were once able to solve.
With class 0, it can no longer be business as usual. State-of-the-art
components are expensive and often in short supply. A failure to
properly confront the threat posed by class 0 device sensitivity will
show up very quickly on the bottom line. It makes no sense to ignore an
inevitable problem that can and should be eliminated by implementing
logical practices. The good news is that those companies that take the
threat seriously and address it preemptively will have the upper hand
in today’s—and tomorrow’s—high tech marketplace. n
Dave Long is the president of StaticWorx, Inc., and can be reached at 617-923-2000 or by e-mail at dave@staticworx.com.
© 2007 Conformity
Top of Page
|